Quality instrument incubator

Quality instrument incubator

The inner wall of the high-quality instrument incubator is covered with a 20mm thick insulation layer. The box is equipped with a heating system and a temperature control device. The electric heater power is user-defined. And can be equipped with pipeline heating source and temperature control device; High quality instrument incubator installation and use: 1. The installation height should not exceed 2000 meters; 2. The cabinet should be installed vertically and fastened with bolts. For outdoor installation, the chassis should be installed. The chassis is prepared on site, and can also be provided by the factory according to user requirements. (The height of the chassis is 200-400mm, and the L40×40×4 angle iron is bent); 3, the insulation of the bottom of the incubator

Product Details

      20mm thick insulation layer on the inner wall of the high-quality instrument incubator . The box is equipped with a heating system and a temperature control device. The electric heater power is user-defined. It can be equipped with pipeline heating source and temperature control device;
Installation and use of high quality instrument incubator:
1. Installation height should not exceed 2000 meters; 2, the cabinet should be installed vertically. Fasten with a bolt. For outdoor installation, the chassis should be installed. The chassis is prepared on site, and can also be provided by the factory according to user requirements. (The height of the chassis is 200-400mm, and the L40×40×4 angle iron is bent);
3. The insulation layer on the bottom of the insulation box can be moved. When the fastening bolts are installed, the movable part of the bottom of the box can be insulated. The layers are removed for easy installation. After installation, install it to the reduction place;
4, the cable is led to the terminal block of the box by the bottom cable joint;
5, other lines are introduced from the rear side of the tube sheet. The tube plate is disassembled;
6. The transmitter is mounted on a mounting tube of 50 mm inside the box. The mounting tube and the two side columns can be moved for any position adjustment during installation. High-quality instrument incubator performance:
1, rated voltage: ~ 220V 50Hz;
2, electric heater power: incubator 500 ~ 2500W adjustable, with heating cable 450 ~ 2400 road ( Length 15~80 meters);
3, temperature adjustable range: 5 ~ 50 ° C;
4, temperature fluctuation range: ± 5 ° C;
5, the box temperature: ≤ 85% ;
6, steam heat: ≤ 200 ° C;
7, steam pressure ≤ 1.6Mpa;
8, insulation strength: ambient temperature 40 ± 5 ° C, relative humidity ≤ 85%, can withstand AC 1000V, 50Hz sine wave for 1 minute withstand voltage test;
9, insulation resistance: ambient temperature ≤ 40 ° C, relative humidity ≤ 85% when the insulation resistance between the conductive part and the box ≥ 20MΩ; > 10, applicable ambient temperature: -50 ~ 60 °C.